Demand Driven Washdown Diversion Systems - Hero

Fox DD600 Demand Driven Stormwater Diversion System

Fox DD600 Demand Driven Stormwater Diversion System – Features & Benefits

Traditionally, large roofs were used to keep rainwater out of the sewer system in washdown areas. But roofs are costly, limit bay size, and still let water in.

Apart from the initial costs involved in roofing a large area, roofs are an inefficient way to protect the sewer from rainwater (wind blown rain will enter the area) roofs also limit the washdown area due to the size and height restraints.

The DD series Diversion Systems are supplied complete, ready to install.

Why use a Fox Washdown Diversion System?

  • Simple to Engineer and design
  • Easy to install
  • No pillars, posts or any above ground structures to restrict access to the area
  • More efficient at protecting the sewer from rainwater, than a roof
  • Does not restrict the size of the wash bay like a roof does
  • Simple automated operation
  • Easy to maintain
  • Huge cost savings to the customer
  • Watermark Certified
  • IAPMO Certified
Unroofed washdown pad layout used with Fox diversion systems
Unroofed Wash Pad Layout
Fox DD600S washdown diversion system
Fox DD600S
Fox diversion valve used in demand‑driven systems
Fox Diversion Valve
Fox patented demand valve component
Fox Patented Demand Valve

Fox DD600 – The Reliable Standard

Fox DD600 Washdown Diversion System

The DD600 is our standard diversion system, installed in hundreds of compliant washdown bays across Australia. It’s a fully certified, general-purpose diversion system ideal for workshops, yards, and industrial sites where reliability and council approval are essential.

Compatible with a range of pit sizes and layouts, the DD600 uses our Fox Demand Valve to automatically detect wash activity and divert washwater to treatment.

Fully automated system. No electrical power required.

Perfect for:

General-purpose unroofed wash bays with moderate sediment loading.

  • Workshops
  • Maintenance depots
  • Rail and logistics yards
  • Fleet wash areas
  • Industrial vehicle wash bays

Key Features:

  • Automatically diverts washwater using the Fox Demand Valve, no power or sensors required
  • Fits a wide range of unroofed washbay sizes and mounting configurations
  • Nationally approved/fully certified to WaterMark standards and EPA/compliance-ready across Australia
📄 Download Spec Sheet

Fox DD600BRT – Extra Stormwater Protection

Fox DD600 BRT Washdown Diversion System

The DD600BRT is designed for unroofed washbays with medium silt loading. It features a built in squid (stormwater quality improvement device) for extra stormwater protection.

Compatible with the same robust Fox demand valve used across the Fox Diversion Valve range. This model provides fully automated stormwater diversion with no power requirements.

Perfect for:

  • Marinas & slipways
  • Truck depots
  • Fuel or maintenance yards
  • High rainfall or exposed washdown areas
  • LV (light vehicle) washdown areas

Key Features:

  • Automatically diverts washwater using the Fox Demand Valve, no power or sensors required
  • Fits a wide range of unroofed washbay sizes and mounting configurations
  • Nationally approved/fully certified to WaterMark standards and EPA/compliance-ready across Australia
  • Fitted with extra stormwater protection (Squid).
📄 Download Spec Sheet

Fox DD600S – Unroofed Bin Wash Application

Fox DD600S Washdown Diversion System

The DD600S offers the same fully automatic diversion capabilities as the standard DD600, but in a compact, slimline pit specifically designed for non trafficable bin wash applications. Designed for space-limited sites, it allows fast, compliant upgrades where standard pits or systems won’t fit.

Because the DD600S does not include a bypass return trap, it’s best suited to controlled washdown areas where runoff can be managed and the pad kept clean between uses.

Perfect for:

  • Non trafficable bin wash area only

Key Features:

  • Slimline footprint for small bin wash areas.
  • Automatically diverts washwater using the Fox Demand Valve, no power or sensors required
  • Fits a wide range of unroofed washbay sizes and mounting configurations
  • Nationally approved/fully certified to WaterMark standards and EPA/compliance-ready across Australia
📄 Download Spec Sheet

Compare Diversion Systems at a Glance

ModelBest ForKey FeatureAdvantage
DD600 Diversion ValveGeneral-purpose wash baysFully automated with class D grate.✔️ Fully hydraulic. No power requirements.
DD600BRT Diversion ValveGeneral purpose/medium light vehicle washbaysAdded stormwater protection (squid)✔️ Fully automated. No power requirements. Complete with added squid.
DD600S Diversion ValveUnroofed bin wash areas.Slimline footprint✔️ Tight installs/small washdown areas


Need to Protect Your Site from Stormwater Contamination?

Fox designs certified diversion and containment systems for industrial and commercial projects. Talk to us for a solution that meets environmental compliance and protects your site from risk.


Proud Members of